What Is an HRV Layout Design?
An HRV (Heat Recovery Ventilator) is a mechanical ventilation unit that continuously exchanges stale indoor air with fresh outdoor air while recovering most of the heat from the outgoing airstream. This keeps indoor air quality acceptable without the energy loss of simply opening a window. An HRV layout design is a set of mechanical drawings that shows where the unit will be installed, how fresh air supply ducts and exhaust ports will be routed, what duct sizes are required for proper airflow, and how the system integrates with any existing forced-air ductwork. These drawings are required documentation for an Ontario building permit on new construction.
Why the Ontario Building Code Requires HRV Documentation
Modern homes are built to be airtight for energy efficiency, which means natural air leakage is no longer sufficient to maintain indoor air quality. The Ontario Building Code requires mechanical ventilation — and HRV documentation — in new residential construction specifically because tight construction without a controlled ventilation system leads to moisture buildup, elevated carbon dioxide levels, and poor air quality. Permit documentation confirms that the ventilation system is properly designed and will deliver the required fresh air volumes to the right locations throughout the house. A building inspector needs to see this documentation before issuing a permit.
What the Drawings Include
Our HRV design package includes a fresh air distribution plan showing supply outlet locations in living areas and bedrooms, exhaust port placement in high-moisture areas such as bathrooms, laundry rooms, and the kitchen, and supply and exhaust duct sizing calculated to deliver proper airflow volumes. Where the HRV connects to an existing forced-air duct system, we show that integration clearly in the drawings. We also provide equipment selection guidance to ensure the unit specified matches the house volume and ventilation requirements. All drawings are BCIN-compliant and formatted for Ontario building permit submission.
Who Needs an HRV Layout Design
Any new home being built in Ontario requires HRV documentation as part of the mechanical drawings package for a building permit. This applies to custom home builders, homeowners managing their own builds, and contractors handling major renovations that involve the ventilation system. In Northern Ontario — including Sudbury, Espanola, North Bay, Manitoulin Island, Elliot Lake, and Sturgeon Falls — we regularly provide HRV layout designs alongside duct or in-floor heating designs as part of a complete mechanical package. If you are already working with us on duct design or radiant floor design, HRV documentation can be included in the same project.
How the Process Works
You provide your floor plans along with basic project details — building location, construction type, number of bedrooms and bathrooms, and any existing duct system information if this is an addition or renovation. We review the plans and calculate the required fresh air volumes based on the Ontario Building Code ventilation requirements for your home's size and occupancy. From there, we produce the layout drawings showing supply and exhaust routing, duct sizing, and equipment placement. The drawings are ready within five business days of receiving a complete project package. If we have questions, we contact you before starting — not partway through.
HRV Design and Energy Efficiency
A well-designed HRV system recovers 70 to 80 percent of the heat from outgoing air and transfers it to incoming fresh air. In Northern Ontario, where heating season runs for six months or more, this recovery makes a meaningful difference in energy consumption compared to exhaust-only ventilation. But the efficiency gains only materialize if the system is properly sized for the house and the ductwork is laid out to distribute air evenly. Oversized units running at low speed waste the recovery core's capacity. Poorly routed supply ducts leave some rooms effectively unventilated. Good design is what makes the equipment perform the way the manufacturer's specifications suggest it should.